Your own mask, then six questions.
The built-in patterns are a start. Everything in litopc also runs on a mask you draw: the simulation, the correction and the studies. One drawn example and six recorded studies below.
Draw your own
Add rectangles, cut a gap, correct.
5.4 → 1.0 nm in 5 rounds (↓81 %). EUV 13.5 nm, NA 0.33: 2 rectangles and one cut drawn as the target, 212 nm field. The cut splits the two bars into two line ends facing each other; the correction pulls the ends out and keeps the gap open.
- Draw
- Edit ▸ Target. Add drags a rectangle onto the canvas; Cut removes one from the shape. Free accounts draw up to 5 rectangles, Pro up to 48.
- Correct
- Correct reshapes the mask edge by edge against your target: 3 rounds per run on Free, 5 on Pro, then more. The mask starts as a copy of the target.
Six studies
One variable swept, every print overlaid, the answer in a line.
- 1Simulate any pattern, built-in or drawn.
- 2Open the Studies tab beside Set-up in the left panel (on a phone, tap Set-up first) and pick a question.
- 3Click a point on the chart, or a row: that print lights up on the canvas.
Recorded simulator output, 2026-11-01. Each caption names the tool and the pattern; Mask bias and MEEF read the same sweep two ways.
Mask bias
Which single bias fits best?
- the reading
- mask
- print, every point
- the reading
- target
- Correct's mask
Grows or shrinks every edge of the combined design by the same amount and measures the miss against the target: rule-based correction in one number, side by side with the model-based result.
- Sweep
- Every edge of the combined mask moves by the same amount, from shrink to grow.
- Reads
- Edge placement error against the target; the best bias is marked.
- Set-up
- DUV 193 nm dry, NA 0.93 · Custom, 110 nm square · τ 0.30 · every edge moved 0 to +24 nm · 1024 nm field
- Run it
- Studies tab ▸ Mask bias, after Simulate.
MEEF (CD linearity)
How much of the mask reaches the wafer?
- wafer = mask
- mask
- print, every point
- the reading
The same uniform edge move as Mask bias, read as wafer CD against mask CD; the slope is the mask error enhancement factor, and the plot shows where the line stops printing.
- Sweep
- The same uniform edge move as Mask bias, written as mask CD.
- Reads
- Printed CD against mask CD; the slope is MEEF, and the plot shows where the line stops printing.
- Set-up
- DUV 193 nm dry, NA 0.93 · isolated 102 nm contact · τ 0.19, its dose-to-size · mask CD 78 to 126 nm
- Run it
- Studies tab ▸ MEEF, after Simulate.
Threshold latitude
How far can the dose drift?
- ±10 % of target
- target
- mask
- print, every point
- the reading
- target
Steps the intensity threshold, the model's stand-in for exposure dose, and reports the span over which CD stays within ±10 % of the target.
- Sweep
- Intensity threshold τ, the model's stand-in for exposure dose.
- Reads
- Printed CD and EPE at each τ; the span that stays within ±10 % of the target.
- Set-up
- DUV 193 nm dry, NA 0.93 · 3 × 3 contact array, 102 nm holes at a 204 nm pitch (Pro pattern) · τ 0.13 to 0.25 around dose-to-size 0.19 · CD of the centre hole
- Run it
- Studies tab ▸ Threshold latitude, after Simulate.
Focus latitude
How much defocus is allowed?
- ±10 % of target
- target
- mask
- print, every point
- the reading
- target
A Bossung curve at the current threshold: printed CD through the tool's depth of focus, with the Rayleigh scale marked.
- Sweep
- Physical defocus through the tool's depth of focus, at the current threshold.
- Reads
- Printed CD per focus step (a Bossung curve); the span that stays in spec.
- Set-up
- EUV 13.5 nm, NA 0.33 · L-shape, 14 nm lines · τ 0.25, its dose-to-size · defocus −90 to +90 nm · CD of the vertical arm
- Run it
- Studies tab ▸ Focus latitude, after Simulate.
Through pitch
How does CD change with pitch?
- target
- mask
- print, every point
- the reading
Sweeps the pitch of the dense-line pattern to show the iso-dense bias OPC has to absorb and the densest pitch that still resolves.
- Sweep
- Pitch of the dense line pattern, at fixed line width.
- Reads
- Printed CD per pitch: the iso-dense bias and the densest pitch that still resolves.
- Set-up
- DUV 193 nm dry, NA 0.93 · Dense lines, three 100 nm lines, 400 nm long · τ 0.30 · pitch 220 to 292 nm · CD of the middle line · 1024 nm field
- Run it
- Studies tab ▸ Through pitch, after Simulate.
Process window
Where do dose and focus both hold?
- in spec
- largest window
A threshold × defocus grid; the largest rectangle of in-spec cells is the window, read as depth of focus at a given threshold latitude.
- Sweep
- Threshold and defocus together, as a grid.
- Reads
- Which cells keep CD in spec; the largest rectangle of them is the window.
- Set-up
- DUV 193 nm dry, NA 0.93 · 150 nm isolated line · τ 0.26 to 0.35 × defocus −180 to +180 nm · in spec within ±10 %
- Run it
- Studies tab ▸ Process window (Pro), after Simulate.